Elegrow TechnologyEngineered to Evolve Discuss Your Project
Home/Services/Power System Studies & Simulation

Power System Studies & Simulation.

Load flow, short circuit, relay coordination, arc flash, harmonics, transients, insulation coordination, grid code compliance, battery sizing and microgrid simulation. Each study answers a question before equipment is bought.

Illustrative image
DeliveryRemoteOn Site
DisciplinesElectrical
Built ForOwners & DevelopersEPC ContractorsOEMsPlant Heads

Is This Where You Are?

Choose your role to see what we do, what changes for you, and what to read next.

What We Do

Compliance study, built to the utility's format — carried straight into your design.

What You GainYour Connection Approved, Not Queried Back

A grid code and compliance study built in the format the connecting utility expects — so the approval that was blocking your Project moves, instead of coming back with another round of questions.

Engineering Scope.

Twelve studies. Each one answers a single question, before equipment is bought.

Load Flow

Can the network carry the load in every operating case?

Short Circuit

Is every piece of equipment rated for the worst fault?

Relay Coordination

Will protection isolate a fault fast, and only where it should?

Arc Flash

What is the hazard at each switchboard, and the PPE it needs?

Earthing

Is the site safe for people during an earth fault?

Harmonics & Power Quality

Will distortion overheat equipment or breach utility limits?

Transient Studies

What happens in the milliseconds after a switch, fault or strike?

Insulation Coordination

Are insulation levels and arresters right for the overvoltages?

Motor Starting

Will large motors start without pulling the voltage down?

Grid Code Compliance

Will the utility approve the connection first time?

Battery Sizing

How much storage, at what power and for how long?

Microgrid Simulation

Does the system stay stable once it separates from the grid?

Also available: contingency and reliability, dynamic RMS simulation, stray current, traction harmonics, EV charging load impact, and N+1 / 2N redundancy for critical facilities.

At Each Project Stage.

Where you are in the Project decides what you need from us.

Feasibility & Concept

Validate viability and size the system before capital is committed.

  • Load flow and network performance
  • Renewable and BESS grid integration feasibility
  • Techno-economic sizing basis

Detailed Design

Set the ratings and settings the whole design depends on.

  • Short circuit and protection coordination
  • Arc flash hazard analysis
  • Insulation coordination and transients
  • Harmonic and grid code compliance

Tender & Procurement

Confirm equipment ratings match the studies before you order.

  • Equipment rating verification against study results
  • Technical bid review

Construction

Studies are frozen; site queries reference them, not repeat them.

  • Design-basis clarifications
  • Settings confirmed for panel and relay ordering

Pre-Commissioning & Commissioning

Prove the settings on the real network before energisation.

  • Relay setting verification support
  • As-built model reconciliation

Operation & Maintenance

Re-study as the network, load or standard changes.

  • Arc flash re-study, typically every 5 years
  • Studies for retrofits, expansions or new loads
  • Harmonics and power quality troubleshooting

Proof in Practice · Pharma · Power Quality

Resolving Power Quality Challenges in a Dual-Source 33 kV API Facility

Diagnosing and fixing power quality problems in an API plant supplied from two 33 kV sources.

Sector
Industrial & Process Plants
Year
2025
Read the Case Study

How We Work on It.

The method behind every engagement. The detail is set out in the proposal and the design basis.

01Define the QuestionWhat decision this study must answer, to what standard.
02Collect DataSingle-line, equipment and utility data.
03Build and ValidateModel checked against known operating points.
04Run the CasesNormal, contingency, fault and time-series.
05ReportSigned, results carried into ratings and settings.
Power System Study Input ChecklistWhat to send before a study starts: single-line, equipment data, utility data and operating cases.
Open Power System Study Input Checklist

Inputs and Deliverables.

A practical starting point and the Engineering outputs to agree for your Project.

01 / Starting information

What We Need from You

  • Single-line diagram
  • Equipment data: transformers, cables, generators, motors, protection
  • Utility fault levels and connection requirements
  • Load, generation and operating scenarios
  • The standard or grid code the study must meet

Send what is available. We will identify missing information before confirming the scope and programme.

02 / Agreed outputs

What You Receive.

  • Study report with assumptions, cases, results and recommendations
  • Protection setting schedules
  • Arc flash results and mitigation plan
  • Harmonic filter design, where needed
  • Grid code compliance results
  • Study models, on request

The exact deliverables are fixed in the agreed scope for each Project.

Standards and Compliance.

We engineer to the standards and regulations that govern your Project, fixed in the design basis.

International StandardsIEC, IEEE, ISO, ASME and API standards, as the Project requires.
National CodesThe codes of the country where the asset is built: BIS and CEA in India, NEC in the USA, BS in the UK, EN in Europe, AS/NZS in Australia, GSO and SASO in the Gulf.
Utility & Authority RequirementsGrid codes, utility specifications and the approvals of the connecting authority.
Client & Lender SpecificationsOwner, licensor and lender requirements, fixed in the design basis.

Typical references for this Service: IEC 60909, IEEE 1584, IEEE 80, IEEE 519, IEC 60071.

Applicable standards and editions are agreed and fixed in each Project's design basis.

How We Assure the Work

ISO 9001:2015-alignedEngineer-signedDocument-controlledIndependentConfidentialRegistered company

Appointed the Way You Need.

Owners and Developers

Owner's Engineer

Feasibility and grid studies, and review of others' studies.

EPC Contractors

Detailed Engineer

Studies that set ratings and settings for the design.

OEMs and Consultants

Design Partner

Specialist studies, white-labelled where required.

We do not act as Detailed Engineer and as Owner's or Independent Engineer on the same Project.

Related Services.

Engineering Design

Where study results become drawings.

View

Technical Audits & Assessments

Arc flash and PQ in operating plants.

View

Testing & Commissioning

Settings proven on site.

View

Questions Clients Ask.

Which studies do you carry out?

Load flow including time-series load flow, short circuit, relay coordination, arc flash, harmonics, transient stability and electromagnetic transients, insulation coordination, grid code compliance, battery sizing, microgrid simulation, earthing and motor starting.

Can you prepare grid connection studies?

Yes, renewable and BESS integration and grid code compliance studies for the connecting utility.

Can you study an existing plant?

Yes. Arc flash, protection and harmonic studies are often the first step to a safer plant.

Read more: Power Quality Audits: Reading Harmonics, Sags and Flicker →
Can you review another consultant's study?

Yes, as Owner's or Independent Engineer, but not where we are also the Detailed Engineer.

Read more: Owner's Engineer or Detailed Engineer: Which Appointment Do You Need? →

Where This Service Applies.

This Service appears in the scope of 6 Sectors. Select a Stage to see the full scope for that Sector.

Enquire Now



This will close in 0 seconds

Enquire Now


    This will close in 0 seconds

    Submit


      This will close in 0 seconds

      Enquire Now


      This will close in 0 seconds

      Enquire Now last



      This will close in 0 seconds

        This will close in 20 seconds

        New contact us form
        Subscribe For

        This will close in 0 seconds

        This will close in 0 seconds

          This will close in 0 seconds

          Cookie Consent Banner by Real Cookie Banner